New Delhi, Delhi
GST No. 07ADRPH9094F1Z1
Approx. Rs 3,82,000 / PieceGet Latest Price
Product BrochureProduct Details:| Minimum Order Quantity | 1 Piece |
| Brand Name | Keeler |
| Type | Desktop |
| Automation Grade | Automatic |
| Portable/Non Portable | Portable |
| Dimensions (HxDxW) | 475 x 410 x 245mm |
| Frequency | 60 Hz |
| Measurment Range | 5mmHg to 50mmHg |
| Power Supply | 100-240V |
| Printer | Yes |
| Working Distance | 20 mm |
| Usage/Application | Clinic, Laboratory, Hospital |
Keeler Pulsair Desktop Non-Contact Tonometer, a precision air-puff tonometer designed for fast, accurate, and comfortable intraocular pressure (IOP) measurement. This desktop model is ideal for glaucoma screening in clinical environments.
�� Keeler Pulsair Desktop Non-Contact Tonometer – Full Specifications�� Measurement Capabilities| Feature | Specification |
|---|---|
| IOP Measurement Range | 5 mmHg to 50 mmHg |
| Display Accuracy | 1 decimal place (e.g., 12.3 mmHg) |
| Measurement Method | Non-contact air puff (IntelliPuff™ technology) |
| Repeatability | Device prompts when two consecutive readings are within ±1 mmHg |
Screen Type: Color video alignment screen
Display Format: Single-line, 16-character alphanumeric display
User Interface: Clear, intuitive controls with visual feedback
Alignment System: Advanced optical and sensor technology for positional detection and puff control
Form Factor: Desktop-mounted with slim optical mainframe
Patient Comfort:
Quiet puff delivery
Reduced anxiety due to open design and visual contact
Visual Contact: Maintains clinician-patient eye contact during alignment
| Feature | Specification |
|---|---|
| Power Supply | Switch-mode power unit (multi-plug type) |
| Input Voltage | 110–240V ±10%, 50/60 Hz |
| Output | 12V DC, 2.5A |
| Power Consumption | 30 VA |
Printer Type: Thermal line printer
Printing Control: Manual or automatic
Accessories: Chinrest paper, printer paper, dust cover
| Feature | Specification |
|---|---|
| Dimensions (HxWxD) | 475 mm × 245 mm × 410 mm |
| Net Weight | 16 kg |
Medical Safety: BS EN 60601-1:2006
EMC Compliance: EN 60601-1-2:2007
Ophthalmic Standards: ISO 15004-1:2006 & ISO 15004-2:2007
Device Class: Class I (non-invasive)
Pulsair Desktop unit
Power supply unit
Dust cover
USB instruction manual
Chinrest papers (1 pack)
Printer paper
Designed, engineered, and hand-assembled in the United Kingdom
Additional Information:
Approx. Rs 32,000 / PieceGet Latest Price
Product BrochureProduct Details:| Minimum Order Quantity | 1 Piece |
| Type | Contact |
| Brand | EYE PLUS |
| Measurement Range | Pressure Range-0 to 80 mmHg |
| Type of Instrument | Tonometer |
| Country of Origin | Made in India |
Applanation Tonometer, which is widely regarded as the gold standard for intraocular pressure (IOP) measurement.
🔬 Applanation Tonometer – Full Specifications📌 General DescriptionAn applanation tonometer measures IOP by determining the force required to flatten a small, predefined area of the cornea. It is typically mounted on a slit lamp and used in clinical settings for glaucoma screening and management.
⚙️ Technical Specifications| Feature | Details |
|---|---|
| Measurement Principle | Applanation Tonometry |
| Measurement Range | 0 to 80 mmHg (in 2 mmHg increments) |
| Contact Area | 3.06 mm diameter flattened corneal zone |
| Accuracy Standard | ISO 8612:2009 compliant |
| Mounting Compatibility | Compatible with slit lamps (e.g., Haag-Streit BM 900, BI 900, BQ 900) |
| Dimensions | Approx. 47 mm (W) × 30 mm (D) × 85 mm (H) |
| Weight | ~800 grams with accessories |
| Materials | Optical-grade glass or methacrylic resin prisms |
| Calibration | Manual calibration bar included; factory calibrated2 |
| Accessories | Measuring prism, calibration bar, prism mount base, optional TB2 base2 |
| Disinfection Option | Tonosafe disposable prisms available for infection control |
High Precision: Reliable and reproducible IOP readings over time.
Durability: Long-lasting mechanical components with minimal maintenance.
Infection Control: Disposable prism options (e.g., Tonosafe) reduce cross-contamination risk.
Optical Clarity: Prisms offer excellent transparency for accurate alignment and measurement.
Integrated Design: Seamless integration with slit lamps for ergonomic use.
Haag-Streit – Classic tonometer with high manufacturing precision
EYE PLUS AATM 1001 – Indian model with full Goldmann compliance
Takagi AT-2 – Compact Z-type tonometer for Takagi slit lamps
Additional Information:
Approx. Rs 26,500 / PieceGet Latest Price
Product BrochureProduct Details:| Minimum Order Quantity | 1 Piece |
| Type | Contact |
| Brand | EYE PLUS |
| Measurement Range | 0 - 10.64 KPa (0 - 80 mmHg) |
| Type of Instrument | Tonometer |
| Country of Origin | Made in India |
YZ30 Applanation Tonometer, a precision instrument designed on the Goldmann principle for accurate intraocular pressure (IOP) measurement. It’s compatible with slit lamps and widely used in ophthalmic clinics and hospitals.
🔬 YZ30 Applanation Tonometer – Full Specifications🧠 Functional Overview| Feature | Specification |
|---|---|
| Primary Use | Measurement of intraocular pressure (IOP) |
| Measurement Principle | Goldmann applanation method |
| Mounting Compatibility |
R & T Types: Haig-Streit style slit lamps
Z Type: Carl Zeiss style slit lamps | | Application Mode | Mounted on slit lamp; direct IOP reading without conversion table2 |
| Feature | Specification |
|---|---|
| Measuring Range | 0 – 10.64 KPa (0 – 80 mmHg)3 |
| Halo Displacement | 1.53 mm × 2 = 3.06 mm (standard Goldmann ring)3 |
| Prism Head Diameter | 7 mm3 |
| Prism Head Movement Range | 3 mm (for alignment and contact)3 |
| Average Error | Less than ±0.066 KPa (±0.5 mmHg)3 |
| Affected Ocular Volume | ~0.56 mm³ (minimal displacement) |
| Feature | Specification |
|---|---|
| Body Material | Precision-machined metal and optical-grade glass |
| Finish | Matte black or silver (anti-reflective coating) |
| Weight | ~300 g |
| Dimensions | 190 mm × 80 mm × 80 mm |
| Mounting Type | Slit lamp bracket with locking screw |
CE-marked
ISO 13485 certified
Designed for contact tonometry with proper sterilization protocols
Measurement unaffected by corneal rigidity2
YZ30 Applanation Tonometer head
Prism head
Mounting bracket (R/T/Z type)
Calibration certificate
Instruction manual
Protective case
Additional Information:
Approx. Rs 1,500 / PieceGet Latest Price
Product BrochureProduct Details:| Minimum Order Quantity | 1 Piece |
| Type | Manual |
| Usage | Clinical |
| Measurement Range | 0 to 20 subdivisions, with an additional 0 to -1 sub-divisions for finer readings |
| Brand | EYE PLUS |
| Item Weight | 200 grams |
| Country of Origin | Made in India |
ECP Schiotz Tonometer with 3 Weights and Plunger, a classic ophthalmic instrument used to measure intraocular pressure (IOP), especially in glaucoma diagnosis:
🩺 ECP Schiotz Tonometer – Full Specifications📦 General Overview| Feature | Specification |
|---|---|
| Brand | ECP (Eye Care Products) |
| Model | Schiotz Tonometer |
| Type | Manual, Mechanical |
| Application | Intraocular Pressure (IOP) Measurement |
| Operation | Manual (Contact-based) |
| Handling | Portable, handheld |
| Feature | Specification |
|---|---|
| Material | High-quality brass (chrome-plated) |
| Plunger Mechanism | Smooth, precision-calibrated |
| Scale Range | 0 to 20 subdivisions and 0 to -1 sub-divisions |
| Pointer | Red needle for easy scale reading |
| Weights Included | 3 calibrated weights: 5.5g, 7.5g, and 10g |
| Measurement Unit | mmHg (millimeters of mercury) |
| Accuracy | High precision with agate bearing |
| Conversion Table | Included for mmHg interpretation |
| Feature | Specification |
|---|---|
| Item Weight | ~200 grams |
| Case Type | Blue deluxe presentation case |
| Sterilization | Easy to sterilize; durable metal construction |
| Country of Origin | Made in India |
Additional Information:
Approx. Rs 8,500 / PieceGet Latest Price
Product BrochureProduct Details:| Minimum Order Quantity | 1 Piece |
| Type | Manual |
| Usage | Hospital |
| Brand | Riester |
| Item Weight | 250 grams |
| Measurement Range | 0 to 20 subdivisions, with an additional 0 to -1 sub-divisions |
Schiotz Tonometer (USA Model)—a classic, mechanical ophthalmic instrument used for measuring intraocular pressure (IOP), especially in glaucoma screening.
�� Schiotz Tonometer (USA Model) – Full Specifications�� General Overview| Feature | Specification |
|---|---|
| Type | Manual, Mechanical |
| Application | Intraocular Pressure (IOP) Measurement |
| Operation | Contact-based, gravity-driven plunger system |
| Usage | Ophthalmology clinics, hospitals, outreach camps |
| Feature | Specification |
|---|---|
| Scale Range | 0 to 20 subdivisions and 0 to -1 sub-divisions |
| Measurement Unit | mmHg (via conversion table) |
| Weights Included | 3 calibrated weights: 5.5g, 7.5g, and 10g |
| Plunger System | Precision-calibrated with agate bearing |
| Pointer | Red needle for easy scale reading |
| Footplate | Curved to conform to corneal surface |
| Material | Non-magnetic, autoclavable stainless steel |
| Finish | Chrome-plated or matte surgical-grade steel |
| Feature | Specification |
|---|---|
| Item Weight | ~200–250 grams |
| Case Type | Deluxe black or blue velvet-lined presentation case |
| Sterilization | Fully autoclavable components |
| Accessories | Conversion chart, test block, cleaning brush |
Typical USA Brands:Riester, Acheron Instruments (exported to USA)
Certifications: ISO-certified, CE-marked (varies by manufacturer)
Availability: Distributed across hospitals, clinics, and surgical centers in the US and globally
Durability: Long service life with minimal maintenance
Additional Information:
Explore More Products
© Eye Vision Products. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited